Linear shoring secured the starting pit.

By laying a new underground power line from the central substation to the northern substation, Innsbrucker Kommunalbetriebe AG has closed the inner-city power line network and increased the security of supply in the city area. The scope of the construction work, for which Kraft & Wärme Rohr- und Anlagentechnik GmbH and TEERAG-ASDAG Aktiengesellschaft as subcontractors were commissioned, includes the crossing of Salurner Straße.

Mainly due to the tense traffic situation, which is characterized by a high volume of passenger cars, bus traffic and a streetcar line, the client had decided to install the required empty pipes for the insertion of the 110 kV lines in a trenchless procedure under the busy crossing area.

Contrary to the original planning, the 3.10 meter wide and 7.80 meter long launch pit required to accommodate the drilling equipment was not secured with sheet piles but with the linear shoring system from EMMUNDS & STAUDINGER by terra infrastructure. In addition to economic aspects, a significant technical aspect was decisive for the decision: In contrast to driving the piles, the construction environment is shaken significantly less when installing the linear shoring.

Flexible and economical: For the stability of the launch pit, the contractor used the linear shoring system from e+s.

A sensible alternative

With linear shoring, shoring panels are held in vertically installed rails so that they can slide past each other. Once installed, the result is a stepped shoring system. The decisive design feature of linear shoring is the rigid roller unit. It ensures that the trench width remains the same during installation and removal in every construction phase - a circumstance that ensures smooth and economical construction processes.

Trench sheeting is generally used for head-end shoring of the launch pit. Since the spreaders of the shoring systems may only be loaded longitudinally in compression and tension and not horizontally, so-called head shoring adapters are integrated into the linear shoring system, which, like the roller unit, are guided in the profile of the linear shoring soldiers, can be adjusted in height at any time and are flush with the head-side edge of the shoring system. In this way, the sheet piles can be supported against the cross girders, which are subject to bending stresses.

As planned, the crossing of Salurner Strasse was completed within the scheduled time frame.

Data & Facts

Builder
Innsbrucker Kommunalbetriebe AG
Delivery
Stepped linear shoring consisting of linear shoring soldiers, inner and outer shoring panels and inner and outer top panels, end shoring including head shoring adapters

you might also be interested in

  • Pioneering achievement on the high seas

    This marks the beginning of a new era in wind energy. The first German wind farm, “alpha ventus”, has been built in 30 meters of water some 45 kilometers north of the island of Borkum.


    To the post
  • Rehabilitation of a Landfill

    For groundwater capture, the landfill was provided with sheet pile walls, which were coated on both sides and provided with a permanent interlock seal.


    To the post
  • Protecting valuable history with terra stop log system

    In a major project here in the hinterland of the Elbe, a combination of a new earth embankment and strengthening of the protective measures by means of demountable stop log elements has been realised.


    To the post